INJ Search

CLOSE


Int Neurourol J > Volume 5(2); 2001 > Article
Clinical Investigation
Journal of the Korean Continence Society 2001;5(2): 64-72.
DOI: https://doi.org/10.5213/jkcs.2001.5.2.64   
The Effect of a 6Fr Transurethral Catheter on the Urinary Flow in Female Pressure-Flow Studies.
Jaeyoung Joung, Hyunsub Cho, Younghwan Ji, Jun Tag Park, Youngjae Kim, Myung Soo Choo
Department of Urology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Korea. mschoo@amc.seoul.kr
ABSTRACT
PURPOSE
We evaluated whether a 6Fr transurethral catheter affects urinary flow in women undergoing pressure-flow studies.
MATERIALS AND METHODS
We retrospectively reviewed urodynamics database of 201 consecutive women referred for the evaluation of lower urinary tract symptoms from January 1997 to June 2000. Before the urodynamic study, all patients voided privately using a standard toilet and free uroflowmetry parameters were recorded. Then, a standard pressure-flow study was performed using 6Fr transurethral catheter. We excluded the patients with inadequate voided volume(<150ml) and volume difference more than 30% between two studies. Urinary flow parameters between the two studies were analysed by paired t-test according to voided volume, main urodynamic diagnosis and uroflowmetry pattern.
RESULTS
Of 201 women, 144 were excluded and 57 were subjects of our analysis. According to voided volume, pressure-flow study parameters were significantly different from the equivalent free uroflowmetry parameters: the maximum flow rate and average flow rate were significantly lower and flow time was significantly longer in pressure-flow studies(p<0.01). According to main urodynamic diagnosis categories, the subgroups of patients with normal urodynamic study, bladder outlet obstruction, detrusor instability and others showed significantly lower maximum flow rate and average flow rate in pressure-flow studies(p<0.01). According to uroflowmetry pattern, obstructive patterns such as undulating and intermittent pattern were more common in pressure-flow studies.
CONCLUSIONS
The 6Fr transurethral catheter used in pressure-flow studies significantly affects urinary flow parameters. In order to make a accurate diagnosis, we must not merely rely on the results of pressure-flow studies, but we must take into account patient's individual clinical situation and also, if available, the results of free uroflowmetry in addition to pressure flow study parameters.
Keywords: Tranurethral catheter; Pressure flow study; Urinary flow
TOOLS
Share :
Facebook Twitter Linked In Google+
METRICS Graph View
  • 0 Crossref
  • 0 Scopus
  • 2,454 View
  • 3 Download
We recommend


ARTICLE & ORGAN
Article Category

Browse all articles >

Organ

Browse all articles >

ISSUES
DISEASES & TOPICS
Diseases

Browse all articles >

Topics

Browse all articles >

AUTHOR
INFORMATION

Official Journal of Korean Continence Society & ESSIC (International Society for the Study of BPS) & Korean Society of Urological Research & The Korean Children’s Continence and Enuresis Society & The Korean Association of Urogenital Tract Infection and Inflammation & Korean Society of Geriatric Urological Care
Editorial Office
Department of Urology, Kangbuk Samsung Medical Center, Sungkyunkwan University School of Medicine,
29 Saemunan-ro, Jongno-gu, Seoul 03181, Korea
Tel: +82-2-2001-2237     Fax: +82-2-2001-2247    E-mail: choys1011@naver.com

Copyright © 2024 by Korean Continence Society.

Developed in M2PI

Close layer
prev next