Efficacy and Safety of Tension-Free Vaginal Tape-Secur Mini-Sling Versus Standard Midurethral Slings for Female Stress Urinary Incontinence: A Systematic Review and Meta-Analysis
Article information
Abstract
Purpose:
To assess the efficacy and safety of tension-free vaginal tape (TVT)-Secur for stress urinary incontinence (SUI).
Methods:
A literature review was performed to identify all published trials of TVT-Secur. The search included the following databases: MEDLINE, Embase, and the Cochrane Controlled Trial Register.
Results:
Seventeen publications involving a total of 1,879 patients were used to compare TVT-Secur with tension-free obturator tape (TVT-O) and TVT. We found that TVT-Secur had significant reductions in operative time, visual analog score for pain, and postoperative complications compared with TVT-O. Even though TVT-Secur had a significantly lower subjective cure rate (P<0.00001), lower objective cure rate (P<0.00001), and higher intraoperative complication rate, compared with TVT-O at 1 to 3 years, there was no significant difference between TVT-Secur and TVT-O in the subjective cure rate (odds ratio [OR], 0.49; 95% confidence interval [CI], 0.22–1.08; P=0.08), objective cure rate (OR, 0.49; 95% CI, 0.22–1.09; P=0.08), or complications at 3 to 5 years. Moreover, TVT-Secur had significantly lower subjective and objective cure rates compared with TVT.
Conclusions:
This meta-analysis indicates that TVT-Secur did not show an inferior efficacy and safety compared with TVT-O for SUI in 3 to 5 years, even though displaying a clear tread toward a lower efficacy in 1 to 3 years. Considering that the safety is similar, there are no advantages in using TVT-Secur.
INTRODUCTION
The International Continence Society defines stress urinary incontinence (SUI) as the complaint of involuntary urine leakage during effort, exertion, sneezing, or coughing [1]. It results from hypermobility of the urethra and functional insufficiency of the urethral sphincter. SUI affects 4% to 35% of women, and the prevalence increases with age [2]. Ten percent of middle-aged women report daily or severe incontinence and at least one-third report leakage at least weekly [3].
SUI management is based on surgical options in case of failure of noninvasive therapies. Placement of a suburethral sling is the gold standard treatment for management of SUI associated with urethral hypermobility [4]. Tension-free vaginal tape (TVT) and tension-free obturator tape (TVT-O) are widely used for this indication, with a high success rate and few complications [5]. Nevertheless, neither is completely free of complications, mainly due to the blind course of the introducer devices. The TVT course may perforate the bladder, whereas TVT-O passage is associated with vaginal perforation and neurologic impairment, leading to protracted thigh pain and upper leg weakness [6]. Both routes occasionally are associated with life-threatening complications, including bowel perforation, major vessel disruption, and perineal gangrene [7]. In addition, voiding dysfunction and vaginal mesh exposures may also complicate midurethral slings (MUS) [8].
Single-incision slings (SIS) were optimized to overcome these complications. TVT-Secur was the first single-incision device, and was developed in 2006. This device can be placed using a retropubic or “U” approach, or a transobturator-like “hammock” approach [9]. The innovation was based on the use of shorter polypropylene laser-cut tape (8 cm×1 cm) through a single vaginal incision in order to avoid the retropubic space, obturator foramen, or groin muscles, and their related nerves and blood vessels.
Moreover, TVT-Secur seemed to cause less postoperative pain and reduced operative time [10], but its effectiveness seemed to be lower in comparison with traditional MUS [11,12]. However, a number of studies reported satisfactory results, including at midterm [13]. The anchoring mechanism of TVT-Secur has been critically evaluated, with studies demonstrating a deterioration over time of the efficacy of this SIS, and calling for long-term studies of the surgical treatment of SUI [14]. Following these contrasting results, TVT-Secur was withdrawn from clinical practice by the manufacturer.
The goal of the present study was to perform a meta-analysis to evaluate the safety and efficacy of TVT-Secur compared with standard MUS in treating SUI, making the evidence available for the many women who had a TVT-Secur device implanted.
MATERIALS AND METHODS
Search Strategy
A systematic literature review was performed in August 2015. The MEDLINE, Embase, and Cochrane Controlled Trial Register databases were searched to identify relevant studies. Searches were restricted to publications in English. Two separate searches were done by applying a free-text protocol with the following search terms: stress urinary incontinence, suburethral slings, tension-free vaginal tape, and randomized controlled trials.
Inclusion Criteria and Trial Selection
Article selection proceeded according to the search strategy based on Preferred Reporting Items for Systematic Reviews and Meta-analysis criteria (Fig. 1). Only studies comparing TVT-Secur and standard MUS were included for further screening. Cited references from the selected articles retrieved in the search were also assessed for significant papers. Conference abstracts were not included because they were not deemed to be methodologically appropriate. Two independent reviewers completed this process, and all disagreements were resolved through consensus.
Quality Assessment
The methodological quality of each study was assessed according to how patients were allocated to the arms of the study, the concealment of allocation procedures, blinding, and the data loss due to attrition. The studies were then classified qualitatively according to the guidelines published in the Cochrane Handbook for Systematic Reviews of Interventions 5.1.0 [15]. Based on the quality-assessment criteria, each study was rated and assigned to one of three quality categories: A, if all quality criteria were adequately met, the study was deemed to have a low risk of bias; B, if one or more of the quality criteria was only partially met or was unclear, the study was deemed to have a moderate risk of bias; or C, if one or more of the criteria were not met, or not included, the study was deemed to have a high risk of bias. Sensitivity analyses were then performed on the basis of whether these quality factors were adequate, inadequate, or unclear. Differences were resolved by discussion among the reviewers.
Data Extraction
Data extracted from each eligible study included the name of the clinical trial, number of patients in each group, the therapy that the patients received, and the country in which the study was conducted. Data including operative time, subjective cure rate, objective cure rate, visual analog score (VAS) for pain, bleeding greater than 100 mL, intraoperative complications, postoperative complications, reoperation for SUI, and de novo urgency were also extracted.
Statistical Analysis
The meta-analysis of comparable data was carried out with Review Manager 5.1.0 (The Cochrane Collaboration, London, UK). Due to the large number of plots, we combined 6 forest plots into 1 plot by using Adobe Photoshop CS (Adobe Systems, San Jose, CA, USA).
RESULTS
Characteristics of Individual Studies
The database search and reference lists of retrieved studies found 267 potential articles for our meta-analysis. Based on the inclusion and exclusion criteria, 194 articles were excluded after reading the titles and abstracts of the articles; 38 articles were not randomized controlled trials (RCTs), and 18 articles lacked useful data. In all, 17 articles [11,12,16-29] with 18 RCTs that compared TVT-Secur with standard MUS (TVT, TVT-O) were included in the analysis. The baseline characteristics of the studies included in our meta-analysis are listed in Table 1.
Quality of Individual Studies
All 18 RCTs were blinded, and all described the randomization processes that they had used. All included a power calculation to determine the optimal sample size (Table 2). The level of quality of each identified study was A to B (Table 2). The funnel plot provided a qualitative estimation of publication bias of the studies, and no evidence of bias was found (Fig. 2).
TVT-Secur Compared With TVT-O at 1 to 3 Years
Efficacy
Operative time (minute): Six RCTs represented 728 participants (360 in the TVT-Secur group and 368 in the TVT-O group) (Fig. 3). Based on our analysis, the pooled estimate of standardized mean difference (SMD) was –0.99, and the 95% confidence interval (CI) was –1.42 to –0.57 (P<0.00001). This result suggests that TVT-Secur showed significant reductions in the mean operative time compared with TVT-O.
Subjective cure rate: Seven RCTs represented 791 participants (388 in the TVT-Secur group and 403 in the TVT-O group) (Fig. 4). According to our analysis, no heterogeneity was found among the trials, and a fixed-effects model was thus chosen for the analysis. Based on our analysis, the pooled estimate of odds ratio (OR) was 0.38, and the 95% CI was 0.27 to 0.54 (P<0.00001). This result suggests that TVT-Secur showed a significantly lower subjective cure rate in comparison with TVT-O.
Objective cure rate: Eleven RCTs represented 1,076 participants (528 in the TVT-Secur group and 548 in the TVT-O group) (Fig. 4). According to our analysis, no heterogeneity was found among the trials, and a fixed-effects model was thus chosen for the analysis. Based on our analysis, the pooled estimate of OR was 0.26, and the 95% CI was 0.19 to 0.37 (P<0.00001). This result suggests that TVT-Secur showed a significantly lower objective cure rate in comparison with TVT-O.
Safety
VAS pain score (postoperative day 1): Three RCTs represented 265 participants (131 in the TVT-Secur group and 134 in the TVT-O group) (Fig. 3). According to our analysis, no heterogeneity was found among the trials, and a fixed-effects model was thus chosen for the analysis. Based on our analysis, the pooled estimate of SMD was –2.15, and the 95% CI was –2.45 to –1.84 (P<0.00001). This result suggests that TVT-Secur showed significant reductions in the VAS score compared with TVT-O.
Bleeding greater than 100 mL: Six RCTs represented 791 participants (402 in the TVT-Secur group and 389 in the TVT-O group) (Fig. 5). According to our analysis, no heterogeneity was found among the trials, and a fixed-effects model was thus chosen for the analysis. Based on our analysis, the pooled estimate of OR was 1.78, and the 95% CI was 0.98 to 3.22 (P=0.06). This result suggests that TVT-Secur showed no significant difference in the rate of bleeding greater than 100 mL compared with TVT-O.
Intraoperative complications: Five RCTs represented 645 participants (325 in the TVT-Secur group and 320 in the TVT-O group) (Fig. 6). According to our analysis, no heterogeneity was found among the trials, and a fixed-effects model was thus chosen for the analysis. Based on our analysis, the pooled estimate of OR was 1.98, and the 95% CI was 1.15 to 3.42 (P=0.01). This result suggests that TVT-Secur showed significant increases in the rate of intraoperative complications compared with TVT-O.
Postoperative complications: Seven RCTs represented 780 participants (392 in the TVT-Secur group and 388 in the TVT-O group) (Fig. 6). According to our analysis, no heterogeneity was found among the trials, and a fixed-effects model was thus chosen for the analysis. Based on our analysis, the pooled estimate of OR was 0.67, and the 95% CI was 0.48 to 0.95 (P=0.03). This result suggests that TVT-Secur showed a significant decrease in the rate of postoperative complications compared with TVT-O.
De novo urgency: Eight RCTs represented 874 participants (439 in the TVT-Secur group and 435 in the TVT-O group) (Fig. 5). According to our analysis, no heterogeneity was found among the trials, and a fixed-effects model was thus chosen for the analysis. Based on our analysis, the pooled estimate of OR was 0.78, and the 95% CI was 0.50 to 1.91 (P=0.25). This result suggests that TVT-Secur showed no significant difference in the rate of de novo urgency compared with TVT-O.
Reoperation for SUI: Four RCTs represented 471 participants (229 in the TVT-Secur group and 242 in the TVT-O group) (Fig. 5). According to our analysis, no heterogeneity was found among the trials, and a fixed-effects model was thus chosen for the analysis. Based on our analysis, the pooled estimate of OR was 4.96, and the 95% CI was 2.37 to 10.35 (P<0.0001). This result suggests that TVT-Secur showed a significant increase in the rate of reoperation for SUI compared with TVT-O.
TVT-Secur Compared With TVT-O at 3 to 5 Years
Subjective cure rate
Two RCTs represented 267 participants (141 in the TVT-Secur group and 126 in the TVT-O group) (Fig. 4). According to our analysis, no heterogeneity was found among the trials, and a fixed-effects model was thus chosen for the analysis. Based on our analysis, the pooled estimate of OR was 0.49, and the 95% CI was 0.22 to 1.08 (P=0.08). This result suggests that TVT-Secur showed no significant difference in subjective cure rate in comparison with TVT-O.
Objective cure rate
Two RCTs represented 267 participants (141 in the TVT-Secur group and 126 in the TVT-O group) (Fig. 4). According to our analysis, no heterogeneity was found among the trials, and a fixed-effects model was thus chosen for the analysis. Based on our analysis, the pooled estimate of OR was 0.49, and the 95% CI was 0.22 to 1.09 (P=0.08). This result suggests that TVT-Secur showed no significant difference in objective cure rate in comparison with TVT-O.
Postoperative complications
Two RCTs represented 282 participants (143 in the TVT-Secur group and 139 in the TVT-O group) (Fig. 6). According to our analysis, no heterogeneity was found among the trials, and a fixed-effects model was thus chosen for the analysis. Based on our analysis, the pooled estimate of OR was 1.20, and the 95% CI was 0.58 to 2.49 (P=0.63). This result suggests that TVT-Secur showed no significant difference in the rate of postoperative complications compared with TVT-O.
TVT-Secur Compared With TVT
Efficacy
Subjective cure rate: Three RCTs represented 444 participants (226 in the TVT-Secur group and 218 in the TVT group) (Fig. 7). According to our analysis, no heterogeneity was found among the trials, and a fixed-effects model was thus chosen for the analysis. Based on our analysis, the pooled estimate of OR was 0.59, and the 95% CI was 0.39 to 0.88 (P=0.01). This result suggests that TVT-Secur showed a significantly lower subjective cure rate in comparison with TVT.
Objective cure rate: Three RCTs represented 248 participants (127 in the TVT-Secur group and 121 in the TVT group) (Fig. 7). According to our analysis, no heterogeneity was found among the trials, and a fixed-effects model was thus chosen for the analysis. Based on our analysis, the pooled estimate of OR was 0.33, and the 95% CI was 0.15 to 0.71 (P=0.004). This result suggests that TVT-Secur showed a significantly lower objective cure rate in comparison with TVT.
Safety
Complications: Four RCTs represented 524 participants (270 in the TVT-Secur group and 254 in the TVT group) (Fig. 8). According to our analysis, no heterogeneity was found among the trials, and a fixed-effects model was thus chosen for the analysis. Based on our analysis, the pooled estimate of OR was 1.12, and the 95% CI was 0.65 to 1.91 (P=0.68). This result suggests that TVT-Secur showed no significant difference in the rate of complications compared with TVT.
DISCUSSION
As a third-generation device, TVT-Secur was first used in 2006. The new so-called minimally invasive devices have been developed to limit groin pain after sling placement while aiming at comparable success results. TVT-Secur minimizes operative dissection and risk of injury of periurethral elements and pelvic organs, as well as the risk of nerve or adductor muscle damage. However, TVT-Secur was withdrawn from clinical practice by the manufacturer due to poor efficacy.
Our study reveals that there was no evidence of significant differences between TVT-Secur and TVT-O for bleeding greater than 100 mL or de novo urgency. There were also no significant differences between TVT-Secur and TVT in complication rates. However, our study found that TVT-Secur has a higher reoperation rate for SUI and intraoperative complication rate compared with TVT-O. Some reports highlighted the risk of severe bleeding following TVT-Secur positioning [30,31]. Larsson et al. [31] recently reported an injury of the corona mortis, an anomaly of the vessels combining the obturator and epigastric arteries passing over the superior pubic ramus. Both cases required surgical intervention to remove clots, identify the site of bleeding, and perform hemostasis. Another report [16] thought that the severe blood loss (approximately 400 mL) experienced by one patient undergoing TVT-Secur was probably from the internal obturator muscle, and was treated conservatively by immediate compression of the muscle with vaginal packing. These data suggest that severe bleeding for TVT-Secur positioning is possible. In the TVT-Secur group, the main postoperative complication was de novo urgency, which may be related to tension difficulties with this kind of device. Higher de novo urgency rates (5%–35%) have been published [18,21], but were not significantly different from the rate observed in the TVT-O group.
Thigh pain is one of the most frequent complications of TVT-O, and TVT-Secur was associated with less postoperative pain [17]. Although we observed a statistical difference in postoperative pain, both groups presented average pain scores<3, which are considered mild according to the VAS [32]. TVT-Secur was associated with less thigh pain than TVT-O, possibly due to absence of involvement of the nerve or adductor muscles. However, all women were free from this symptom within a month following surgery. Moreover, operative time was significantly reduced in the TVT-Secur group.
Our meta-analysis indicated that TVT-Secur had significantly worse subjective and objective outcomes than standard MUS at 1 to 3 years. However, at 3 to 5 years, we found that there was no significant difference in subjective or objective cure rates in comparison with TVT-O. The subjective and objective cure rate of TVT-Secur is 69.7% and 70% at 1 to 3 years, and 59.7% and 78% at 3 to 5 years, respectively. Tommaselli et al. [23] recently reported that subjective success (63.8%) and objective cure rates (68.4%) over 5 years were lower for TVT-Secur than TVT-O, but not significantly. The reason may be that many patients with TVT-Secur who failed at 1 to 3 years may have had other operations, which were not included at 3 to 5 years of follow-up. Moreover, in comparison with the 36-month follow-up, TVT-Secur showed a greater decrease in subjective cure rate than TVT-O [23]. These data seem to indicate that the subjective cure rate of TVT-Secur decreases over time more than that of TVT-O, although not significantly. Indeed, a limitation of our study is the sample size of patients. With a larger sample size, the study may demonstrate a difference in outcomes between TVT-Secur and TVT-O at 3 to 5 years. As for objective cure rate, this discrepancy may be explained by the fact that objective evaluation may not reflect normal daily activities, and thus underestimates the incidence of recurrent SUI. The fact that TVT-Secur has been associated with lower cure rates deserves some consideration. The failure at 1–3 years is mainly linked to an incorrect positioning or early failure of the sling, and recurrences are probably due to insufficiency of the tape in avoiding SUI. As for the many women who had a TVT-Secur device implanted, reoperation is a problem. The clinical relevance of the decline of the efficacy of TVT-Secur, and the limited advantages of this device in the long-term, in particular, suggest that TVT-O may be a better choice, when all factors are considered.
In summary, TVT-Secur failed to demonstrate high clinical efficacy for SUI. Indeed, only 70.8% of patients treated with TVT-Secur remained cured, whereas 90.7% of patients treated with TVT-O remained cured after a median follow-up of 32 months. These results are influenced by previous incontinence surgery and a cystocele grade ≥2 [33]. Multivariate analysis also showed that only low Valsalva leak point pressure<60 cm H2O was associated with a lower cure rate [34]. Therefore, these factors should be carefully evaluated when choosing a TVT-Secur procedure, to provide sufficient information to patients. TVT-O or TVT are still the first-line treatments for female SUI.
This meta-analysis includes studies in which all findings are from randomized double-blind, placebo-controlled trials. According to the quality-assessment scale that we developed, the quality of the individual studies in the meta-analysis was conforming. The results of this analysis acquire great importance from a scientific standpoint, but also for daily clinical practice. However, the number of included studies was not large. Longer-term safety, efficacy, and stability of TVT-Secur cannot be extrapolated from this article, as the sample size is limited. In addition, unpublished data were not included in the analysis. Besides, there is a discrepancy in the number of parameters used in comparing the procedures. Nine parameters were evaluated for the analysis of TVT-Secur compared with TVT-O at 1 to 3 years. As the data were limited, a carefully structured analysis comparing TVT-S with TVT-O at 3 to 5 years could not be done, and only 3 parameters were evaluated. This may compromise the value of the study results, and these factors may have resulted in bias. More high-quality trials with larger samples are proposed to learn more about the efficacy and safety of the therapy for female SUI.
In conclusion, this meta-analysis indicates that TVT-Secur did not show an inferior efficacy and safety compared with TVT-O for SUI in 3 to 5 years, even though displaying a clear tread toward a lower efficacy in 1 to 3 years. Considering that the safety is similar, there are no advantages in using TVT-Secur.
Notes
Fund Support
This study was supported by the Capital Characteristic Clinical Project of China.
Conflict of Interest
No potential conflict of interest relevant to this article was reported.